Product Configurator

Part Number Formula

EXAMPLE

1(req.) 2(req.) 3(req.) 4(req.) 5(req.) 6(opt.)

LV1A-

H-

4L-

1200A-

480V-

CGUF

1    THIS FIELD REPRESENTS ONE OF THE FOLLONG:  (this field is required)

  • LV = Low Voltage – < 1 volt to 1 kilovolt
  • LV1A =  Low Voltage – manufactured to MIL-STD-188-125-1A
  • MV5K = Medium Voltage1 kilovolt to 15 kilovolt

       Note: all low voltage markings for MIL-STD 188-125-1A filters are followed by 1A.

2    THIS FIELD REPRESENTS FILTER TYPE: (this field is required)

  • H = HEMP POWER
  • HD = HEMP DATA
  • HC = HEMP CONTROL
  • HT = HEMP TEMPEST
  • T = TEMPEST POWER
  • TC = TEMPEST CONTROL
  • TD = TEMPEST DATA

3    THIS FIELD REPRESENTS FILTER CONFIGURATION AND NUMBER OF LINES: (this field is required) 

     Total number of lines “phases & neutral” this example reflects a modular four-line filter.
     a modular filter “removable from housing”.

     NOTE: for an integrated “one piece” filter and housing, field will start with:
     C = COMPOSITE – example: C4L

4    THIS FIELD REPRESENTS FILTER CURRENT RATING FOLLOWED BY: (this field is required) 

     A = AMPERAGE – example: 1200A                                       

5    THIS FIELD REPRESENTS FILTER VOLTAGE RATING: (this field is required) 

     Standard Voltage Options as follows:

Voltage Alternating Current – 120, 250 or 480  Followed by: V = VAC

Voltage Direct Current – 24, 48 or  72  Followed by: DC = VDC

NOTE: Customer may define an alternitive voltage rating.   

6   DOCUMENT PACKAGE FIELD-OPTIONS AS FOLLOWS: (this field is required) 

  1. CG – CRADLE TO GRAVE includes Standard Production Test Results
  2. UF –Meets USFG 13 49 20.00 10 Production Test Requirements
  3. CGUF – CRADLE TO GRAVE  TSS Standard Production Test Results & Meets USFG 13 49 20.00 10 Test Requirements
  4. MS188 – INCLUDES PCI TESTING AND CGUF DOCUMENT PACKAGE

Custom Part # Add On

Custom part numbers are assigned for filters not offered as a TSS standard :

  • filter performance
  • housing dimensions or penetrations

EXAMPLE

1(req.) 2(req.) 3(req.) 4(req.) 5(req.) 6(opt.)  7 (opt.)

LV1A-

H-

4L-

1200A-

480V-

CGUF

GOL0222

7    This field is comprised of: (this field is required as needed)

  • The first three letters are the customer designation.
    GOL = Goliath LLC.
  • The last four numbers represent month and year.
    02 = month of February   22 = the year 2022

Our team of experts can guide you through the filter selection process with our engineering services available to you at no extra charge.